Practices

The Commission is in the process of updating some of the content on this website in light of the withdrawal of the United Kingdom from the European Union. If the site contains content that does not yet reflect the withdrawal of the United Kingdom, it is unintentional and will be addressed.

Please, keep in mind that the only contact email for BUILD UP is contact@buildup.eu, any other address, even if similar, is not under our domain.

Edificio Ceres, Madrid - Passive House Building

Share this Post:

Credits: Grupo Lobe

Edificio Ceres is a residential block in the shape of a letter C located in Valdemoro. It contains 90 dwellings divided into 8 staircases, of which 62 are free while 28 are public protection VPPL. Most of the dwellings have 3 bedrooms with an average surface area of 83 m2 per dwelling and various orientations. Other homes have 2 and 4 bedrooms. The homes are equipped with terraces, garage, storage room and communal area with swimming pool.

 

The building has 6 floors above ground level and 2 floors below ground level for garage and storage rooms. The ground floor has access to the building and commercial premises. Six staircases have 2 flats per floor except in the attic, where it has 1 or 2 flats. The corner staircases have 3 flats per floor, reducing to 2 on the top floor.

 

THERMAL ENVELOPE

 

Exterior wall: U-value = 0.2 W/(m2K)

Basement floor / floor slab: U-value = 0.19 W/(m2K)

Roof: U-value = 0.23 W/(m2K)

Frame: Deceuninck, Legend
U w-value = 1.05 W/(m2K)

Glazing: U g-value = 0.57 W/(m2K)
Entrance door: U d-value = 1.96 W/(m2K)

 

PHPP VALUES

 

Climate: Warm, temperate

Air tightness: n50 = 0.36/h

Annual heating demand: 13 kWh /(m2a ) calculated according to PHPP

Heating load: 8 W/m2

PE demand (non-renewable Primary Energy): 93 kWh /(m2a ) on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP

PER demand (renewable Primary Energy): 103 kWh /(m2a ) on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP

 

Find more details here.

Award labels

Available link languages