Filiale Kirchheimbolanden - Germany

Istaknut Je Slučaj Highlighted Case
Share this Post:

This 600 square-metre plot was used to erect a new service centre that would not only encompass a bank branch but also consultation rooms for customers and staff. Overall the building spans a total usable floor area of 1800 square metres. The energy consultant used dynamic computer simulations and local climate records to design the building and select materials.

 

The aim was to maintain comfortable room temperatures in the summer and the winter, deliver good air quality, provide sufficient lighting and control noise levels inside the building. Fundamental factors in providing a comfortable indoor environment include ensuring the building points in the right direction and coming up with the right design.

 

Furthermore, a low-tech climate-control system was fitted in the building based on efficient energy. Combining this with local, renewable energy made it possible to achieve a positive net annual energy rating. Concrete core activation is used to heat and cool the building. In most parts of the building, ventilation is provided as naturally as possible by opening windows. As a result, this building is an outstanding example of how to operate a building in an environmentally positive manner based on a low-tech climate-control concept.

 

AT A GLANCE.

 

Award Climate Positive*

Year of the award: 2019

Valid to: September 2020

Location: Kirchheimbolanden, Germany

Applicant: Volksbank Alzey-Worms eG

Client: Volksbank Alzey-Worms eG

Architect: Karl Irmler GmbH

Energy concept and CO2 balancing: TRANSSOLAR Energietechnik GmbH

 

* This award is bestowed for buildings that achieve a negative annual carbon footprint and thus make a significant positive contribution to climate protection. The net carbon footprint assessment is based on the DGNB Framework for Carbon-Neutral Buildings and Sites.

Award labels