Practices

NHT - Burgeck - JE29E (Jenbach -Austria)

Share this Post:

This new residential complex in Tirol, completed in 2018, is a passive house construction with 20 condominiums, 19 underground parking spaces and 8 carport spaces. The structure is U-shaped and is divided, due to the slope, in a basement with underground parking, a ground floor and 4 other above-ground floors.

 

The outstandingly low levels of energy demand and consequential CO2 emissions have made it achieve the Bronze status of the Austrian klimaaktiv criteria.

 

BUILDING DETAILS 

Method of construction: Concrete Structures

Number of residential units: 20

Number of floors: 5

Cond. Gross floor area: 2091 m²

Usable area: 1378.1 m²

Heating system space heating: heat pump

Heating system hot water: electricity

 

  

PLANNING AND EXECUTION 

At least 2 infrastructures at 1.000 m: Yes

energy monitoring: Yes

Blower Door Test (n50 value): 0.35 h -1

 

 

ENERGY AND SUPPLY 

Energy data calculated according to OIB guideline 6 - 2015

Heating demand: 21.2 kWh / m² 

Primary energy demand: 79.7 kWh / m² 

CO 2 emissions: 11.5 kgCO 2 / m² 

 

 

BUILDING MATERIALS AND CONSTRUCTION

HFC-free insulating materials and mounting foams: Yes

 

 

COMFORT AND INDOOR AIR QUALITY 

Proof of summer suitability: Yes

Room air measurement VOC: 470 μg / m³

Room air measurement formaldehyde: 0.0082 mg / m³

Award labels