The extension and renovation of this office building has been done through a low-tech approach which consists of three main components:

  • sufficiency: using as few resources as possible
  • efficiency: having as little energy consumption as possible, thus permanently saving costs and ensuring comfort
  • climate protection: 100% renewable energy and maximum energy self-sufficiency

Thermal envelope

Exterior wall: Rigips Rigidur H 15 - 20 mm
Air layer dormant - 10 mm
Steicoflex WLS 040 - 30 mm
Wood-based panel - 15 mm
Cellulose/wood - 240 mm
DWD board - 16 mm

U-value = 0.149 W/(m2K)

 

Basement floor/floor slab: Wood covering - 25 mm
Air layer dormant - 10 mm
Steicoflex WLS 040 - 30 mm
wood-based panel - 15 mm
Cellulose/wood - 280 mm
Rigips Glasroc X 13 mm

U-value = 0.133 W/(m2K)

Roof: Wood acoustic ceiling - 20 mm
Air layer dormant - 40 mm
Wood-based panel - 15 mm
Cellulose/wood - 280 mm
MDF sub-ceiling board - 16 mm

U-value = 0.152 W/(m2K)

PHPP values

Air tightness: n50 = 0.81/h

Annual heating demand: 30 kWh /(m2a ) calculated according to PHPP

PE demand (non-renewable Primary Energy): 104 kWh /(m2a ) on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP

PER demand (renewable Primary Energy): 62 kWh /(m2a ) on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP